Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
J Med Microbiol ; 73(4)2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38591530

RESUMO

Sexually transmitted infections (STI) are a public health problem. Real-time PCR assays are the most sensitive test for screening and diagnosis of these infections. The aim of this study was to evaluate a new CT/NG/TV/MG Real-Time PCR (RT-PCR) kit (Vircell) for the detection of Chamydia trachomatis, Neisseria gonorrhoeae, Mycoplasma genitalium and Trichomonas vaginalis for the diagnosis of sexual transmitted infections using the Allplex STI Essential Assay (Seegene) as the reference's method. A total of 497 samples from different anatomical sites (endocervical, urethral, rectal, pharyngeal and urine) were analysed from October 2022 to February 2023. A total of 108 (21.73 %) and 106 (21.33 %) positive samples were found for any of the assays used. The most commonly detected pathogen was N. gonorrhoeae (52 samples; 10.46 %), and the least commonly detected was T. vaginalis (three samples; 0.60 %). The anatomical site with the highest prevalence of micro-organisms was a non-urogenital site, the pharynx (26 positive samples; 5.23 %). Using the Allplex STI Essential Assay (Seegene) as the reference method, the diagnosis performance showed that the average specificity of CT/NG/TV/MG RT-PCR Kit (Vircell) was 99.84 % and the sensitivity was 99.53 %. The overall concordance was k=0.98 (CI95 %; 0.96-1). In conclusion, the CT/NG/TV/MG RT-PCR Kit (Vircell) assay shows a good sensitivity and specificity and constitutes a promising and additional alternative to routine procedures for distinct types of clinical specimen in diagnosis STI.


Assuntos
Infecções por Chlamydia , Gonorreia , Infecções por Mycoplasma , Mycoplasma genitalium , Infecções Sexualmente Transmissíveis , Trichomonas vaginalis , Humanos , Reação em Cadeia da Polimerase em Tempo Real , Chlamydia trachomatis/genética , Infecções Sexualmente Transmissíveis/diagnóstico , Infecções Sexualmente Transmissíveis/epidemiologia , Trichomonas vaginalis/genética , Neisseria gonorrhoeae/genética , Mycoplasma genitalium/genética , Infecções por Mycoplasma/diagnóstico , Infecções por Mycoplasma/epidemiologia , Tomografia Computadorizada por Raios X , Infecções por Chlamydia/diagnóstico , Gonorreia/diagnóstico , Gonorreia/epidemiologia
2.
J Clin Oncol ; : JCO2301841, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38603646

RESUMO

PURPOSE: Measurable residual disease (MRD) by using flow cytometry after induction therapy is strongly prognostic in pediatric AML, and hematopoietic stem-cell transplant (hSCT) may counteract a poor response. We designed a phase III study with intensified response-guided induction and MRD-based risk stratification and treated poor induction response with hSCT. The efficacy of liposomal daunorubicin (DNX) in induction was compared with mitoxantrone. METHODS: The study planned to randomly assign 300 patients, but the production of DNX ceased in 2017. One hundred ninety-four patients were randomly assigned to mitoxantrone or experimental DNX in induction 1. Ninety-three non-randomly assigned patients served as an observation cohort. Primary end point was fraction of patients with MRD <0.1% on day 22 after induction 1. Patients with MRD ≥15% after induction 1 or ≥0.1% after induction 2 or FLT3-ITD with NPM1 wildtype were stratified to high-risk therapy, including hSCT. RESULTS: Outcome for all 287 children was good with 5-year event-free survival (EFS5y) 66.7% (CI, 61.4 to 72.4) and 5-year overall survival (OS5y) 79.6% (CI, 75.0 to 84.4). Overall, 75% were stratified to standard-risk and 19% to high-risk. There was no difference in the proportion of patients with MRD <0.1% on day 22 after induction 1 (34% mitoxantrone, etoposide, araC [MEC], 30% DNX, P = .65), but the proportion increased to 61% for MEC versus 47% for DNX (P = .061) at the last evaluation before induction 2. EFS5y was significantly lower, 56.6% (CI, 46.7 to 66.5) versus 71.9% (CI, 63.0 to 80.9), and cumulative incidence of relapse (CIR) was higher, 35.1% (CI, 25.7 to 44.7) versus 18.8% (CI, 11.6 to 27.2) for DNX. The inferior outcome for DNX was only in standard-risk patients with EFS5y 55.3% (CI, 45.1 to 67.7) versus 79.9% (CI, 71.1 to 89.9), CIR 39.5% (CI, 28.4 to 50.3) versus 18.7% (CI, 10.5 to 28.7), and OS5y 76.2% (CI, 67.2 to 86.4) versus 88.6% (CI, 81.4 to 96.3). As-treated analyses, including the observation cohort, supported these results. For all high-risk patients, 85% received hSCT, and EFS5y was 77.7 (CI, 67.3 to 89.7) and OS5y was 83.0 (CI, 73.5 to 93.8). CONCLUSION: The intensification of induction therapy with risk stratification on the basis of response to induction and hSCT for high-risk patients led to improved outcomes. Mitoxantrone had a superior anti-leukemic effect than liposomal daunorubicin.

3.
Biosensors (Basel) ; 14(3)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38534256

RESUMO

A proof-of-concept of a microwave imaging system for the fast detection of abdominal aortic aneurysms is shown. This experimental technology seeks to overcome the factors hampering the fast screening for these aneurysms with the usual equipment, such as high cost, long-time operation or hazardous exposure to chemical substances. The hardware system is composed of 16 twin antennas mastered by a microcontroller through a switching network, which connects the antennas to the measurement instrument for sequential measurement. The software system is run by a computer, mastering the whole system, automatizing the measurement process and running the signal processing and medical image generation algorithms. Two image generation algorithms are tested: Delay-and-Sum (DAS) and Improved Delay-and-Sum (IDAS). Own-modified versions of these algorithms adapted to the requirements of our system are proposed. The system is carefully calibrated and fine-tuned with known objects placed at known distances. An experimental proof-of-concept is shown with a human torso phantom, including an aorta phantom and an aneurysm phantom placed in different positions. The results show good imaging capabilities with the potential for detecting and locating possible abdominal aortic aneurysms and reporting acceptable errors.


Assuntos
Aneurisma da Aorta Abdominal , Imageamento de Micro-Ondas , Humanos , Aneurisma da Aorta Abdominal/diagnóstico , Software , Algoritmos , Imagens de Fantasmas
4.
Front Immunol ; 15: 1307932, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38370416

RESUMO

Introduction: Hematopoietic stem cell transplantation (HCT) can cure chronic granulomatous disease (CGD). However, transplant-associated morbidity or mortality may occur, and it is still controversial which patients benefit from this procedure. The aim of this retrospective study was to evaluate the outcome of pediatric patients who received HCT in one of the Spanish pediatric transplant units. Results: Thirty children with a median age of 6.9 years (range 0.6-12.7) were evaluated: 8 patients received a transplant from a sibling donor (MSD), 21 received a transplant from an unrelated donor (UD), and 1 received a haploidentical transplant. The majority of the patients received reduced-intensity conditioning regimens based on either busulfan plus fludarabine or treosulfan. Relevant post-HCT complications were as follows: i) graft failure (GF), with a global incidence of 28.26% (CI: 15.15-48.88), 11.1% in patients with MSD (1.64-56.70) and 37.08% in unrelated donors (19.33-63.17); and ii) chronic graft-versus-host disease (GVHD), with an incidence of 20.5% (8.9-43.2), 11.1% in patients with MSD (1.64-56.70) and 26.7% in unrelated donors (10.42-58.44). Post-HCT infections were usually manageable, but two episodes of pulmonary aspergillosis were diagnosed in the context of graft rejection. The 2-year OS was 77.3% (55.92-89.23). There were no statistically significant differences among donor types. Discussion: HCT in patients with CGD is a complex procedure with significant morbidity and mortality, especially in patients who receive grafts from unrelated donors. These factors need to be considered in the decision-making process and when discussing conditioning and GVHD prophylaxis.


Assuntos
Doença Enxerto-Hospedeiro , Doença Granulomatosa Crônica , Transplante de Células-Tronco Hematopoéticas , Humanos , Criança , Lactente , Pré-Escolar , Doença Granulomatosa Crônica/complicações , Estudos Retrospectivos , Doença Enxerto-Hospedeiro/prevenção & controle , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Transplante de Células-Tronco Hematopoéticas/métodos , Doadores não Relacionados
5.
Transplant Cell Ther ; 29(11): 702.e1-702.e11, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37595686

RESUMO

Increasing data on treosulfan-based conditioning regimens before hematopoietic stem cell transplantation (HSCT) demonstrate the consistent benefits of this approach, particularly regarding acute toxicity. This study aimed to describe the results of treosulfan-based conditioning regimens in children, focusing on toxicity and outcomes when used to treat both malignant and nonmalignant diseases. This retrospective observational study of pediatric patients treated in Spain with treosulfan-based conditioning regimens before HSCT was based on data collection from electronic clinical records. We studied a total of 160 treosulfan-based conditioning HSCTs to treat nonmalignant diseases (n = 117) or malignant diseases (n = 43) in 158 children and adolescents. The median patient age at HSCT was 5.1 years (interquartile range, 2 to 10 years). The most frequent diagnoses were primary immunodeficiency (n = 42; 36%) and sickle cell disease (n = 42; 36%) in the nonmalignant disease cohort and acute lymphoblastic leukemia (n = 15; 35%) in the malignant disease cohort. Engraftment occurred in 97% of the patients. The median times to neutrophil engraftment (17 days versus 14 days; P = .008) and platelet engraftment (20 days versus 15 days; P = .002) were linger in the nonmalignant cohort. The 1-year cumulative incidence of veno-occlusive disease was 7.98% (95% confidence interval [CI], 4.6% to 13.6%), with no significant differences between cohorts. The 1-year cumulative incidence of grade III-IV acute graft-versus-host disease (GVHD) was higher in the malignant disease cohort (18% versus 3.2%; P = .011). Overall, the malignant cohort had both a higher total incidence (9% versus 3%; P < .001) and a higher 2-year cumulative incidence (16% versus 1.9%; P < .001) of total chronic GVHD. The 2-year cumulative transplantation-related mortality was 15%, with no difference between the 2 cohorts. The 5-year overall survival was 80% (95% CI, 72% to 86%) and was higher in the nonmalignant cohort (87% versus 61%; P = .01). The 2-year cumulative incidence of relapse was 25% in the malignant cohort. The 5-year cumulative GVHD-free, relapse-free survival rate was 60% (95% CI, 51% to 70%) and was higher in the nonmalignant cohort (72% versus 22%; P < .001). A treosulfan-based radiation-free conditioning regimen is feasible, achieving a high engraftment rate and 5-year overall survival, and is an emerging option for the first HSCT in nonmalignant diseases.


Assuntos
Doença Enxerto-Hospedeiro , Transplante de Células-Tronco Hematopoéticas , Neoplasias , Adolescente , Criança , Humanos , Pré-Escolar , Estudos Retrospectivos , Condicionamento Pré-Transplante/métodos , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Doença Enxerto-Hospedeiro/epidemiologia , Doença Enxerto-Hospedeiro/etiologia , Doença Enxerto-Hospedeiro/prevenção & controle
6.
Biosensors (Basel) ; 13(7)2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37504116

RESUMO

The heart rate (HR) is a widely used clinical variable that provides important information on a physical user's state. One of the most commonly used methods for ambulatory HR monitoring is photoplethysmography (PPG). The PPG signal retrieved from wearable devices positioned on the user's wrist can be corrupted when the user is performing tasks involving the motion of the arms, wrist, and fingers. In these cases, the obtained HR is altered as well. This problem increases when trying to monitor people with autism spectrum disorder (ASD), who are very reluctant to use foreign bodies, notably hindering the adequate attachment of the device to the user. This work presents a machine learning approach to reconstruct the user's HR signal using an own monitoring wristband especially developed for people with ASD. An experiment is carried out, with users performing different daily life activities in order to build a dataset with the measured signals from the monitoring wristband. From these data, an algorithm is applied to obtain a reliable HR value when these people are performing skill improvement activities where intensive wrist movement may corrupt the PPG.


Assuntos
Transtorno do Espectro Autista , Fotopletismografia , Humanos , Frequência Cardíaca/fisiologia , Fotopletismografia/métodos , Artefatos , Processamento de Sinais Assistido por Computador , Movimento (Física) , Algoritmos
7.
Sensors (Basel) ; 22(23)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36502071

RESUMO

Epileptic seizures have a great impact on the quality of life of people who suffer from them and further limit their independence. For this reason, a device that would be able to monitor patients' health status and warn them for a possible epileptic seizure would improve their quality of life. With this aim, this article proposes the first seizure predictive model based on Ear EEG, ECG and PPG signals obtained by means of a device that can be used in a static and outpatient setting. This device has been tested with epileptic people in a clinical environment. By processing these data and using supervised machine learning techniques, different predictive models capable of classifying the state of the epileptic person into normal, pre-seizure and seizure have been developed. Subsequently, a reduced model based on Boosted Trees has been validated, obtaining a prediction accuracy of 91.5% and a sensitivity of 85.4%. Thus, based on the accuracy of the predictive model obtained, it can potentially serve as a support tool to determine the status epilepticus and prevent a seizure, thereby improving the quality of life of these people.


Assuntos
Eletroencefalografia , Epilepsia , Humanos , Eletroencefalografia/métodos , Qualidade de Vida , Convulsões/diagnóstico , Epilepsia/diagnóstico , Aprendizado de Máquina
8.
Expert Rev Anticancer Ther ; 22(11): 1183-1196, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36191604

RESUMO

INTRODUCTION: Pediatric acute myeloid leukemia (AML) is the second most common type of pediatric leukemia. Patients with AML are at high risk for several complications such as infections, typhlitis, and acute and long-term cardiotoxicity. Despite this knowledge, there are no definite supportive care guidelines as to what the best approach is to manage or prevent these complications. AREA COVERED: The NOPHO-DB-SHIP (Nordic-Dutch-Belgian-Spain-Hong-Kong-Israel-Portugal) consortium, in preparation for a new trial in pediatric AML patients, had dedicated meetings for supportive care. In this review, the authors discuss the available data and outline recommendations for the management of children and adolescents with AML with an emphasis on hyperleukocytosis, tumor lysis syndrome, coagulation abnormalities and bleeding, infection, typhlitis, malnutrition, cardiotoxicity, and fertility preservation. EXPERT OPINION: Improved supportive care has significantly contributed to increased cure rates. Recommendations on supportive care are an essential part of treatment for this highly susceptible population and will further improve their outcome.


Assuntos
Leucemia Mieloide Aguda , Tiflite , Adolescente , Criança , Humanos , Leucemia Mieloide Aguda/terapia , Leucemia Mieloide Aguda/patologia , Cardiotoxicidade
9.
J Clin Apher ; 37(6): 573-583, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36134700

RESUMO

INTRODUCTION: Graft-vs-host disease (GVHD) is a frequent cause of morbidity and mortality in allogeneic stem cell transplants. Extracorporeal photopheresis (ECP) is one of the most accepted second-line treatments, but technical issues of ECP in children might be prohibitive. MATERIALS AND METHODS: Patients under 18 y of age with corticodependant or corticorefractory GVHD receiving ECP at our hospital were included in this retrospective study. ECP was performed with an in-line system (CellExTherakos) in 2013-2014 and with an off-line system (Spectra Optia) from 2015 onwards. Cumulative incidence curves were obtained to compare ECP efficacy among patients grouped by different baseline, apheresis, and disease characteristics. Significant variables on univariate analysis (Gray's test) were pooled into a multivariate analysis (Fine-Gray proportional hazard regression for competing events). RESULTS: A total of 701 ECP sessions were performed on 33 patients between October 2013 and December 2021. In total, 97% of the sessions could be executed. In 8% of the sessions an incident was detected, most of them mild and related to catheter dysfunction. With a median follow-up for alive patients of 33.6 mo (range, 8-95), the composite partial and complete response cumulative incidence was 70% (95% confidence interval, 51%-82%) and the median time to maximal response was 2.8 mo (range, 0.25-9.8). Significantly lower response ratios were found in patients with hepatic, gastrointestinal, acute, or severe GVHD. The only variable that influenced response on multivariate analysis was GVHD severity. DISCUSSION: ECP is feasible, safe, and effective for pediatric patients with corticorefractory or corticodependant GVHD, offering a less toxic and nonimmunosuppressive treatment option.


Assuntos
Doença Enxerto-Hospedeiro , Transplante de Células-Tronco Hematopoéticas , Fotoferese , Humanos , Criança , Doença Enxerto-Hospedeiro/terapia , Estudos Retrospectivos , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Indução de Remissão
10.
Sensors (Basel) ; 22(8)2022 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-35458883

RESUMO

Epilepsy is a chronic disease with a significant social impact, given that the patients and their families often live conditioned by the possibility of an epileptic seizure and its possible consequences, such as accidents, injuries, or even sudden unexplained death. In this context, ambulatory monitoring allows the collection of biomedical data about the patients' health, thus gaining more knowledge about the physiological state and daily activities of each patient in a more personalized manner. For this reason, this article proposes a novel monitoring system composed of different sensors capable of synchronously recording electrocardiogram (ECG), photoplethysmogram (PPG), and ear electroencephalogram (EEG) signals and storing them for further processing and analysis in a microSD card. This system can be used in a static and/or ambulatory way, providing information about the health state through features extracted from the ear EEG signal and the calculation of the heart rate variability (HRV) and pulse travel time (PTT). The different applied processing techniques to improve the quality of these signals are described in this work. A novel algorithm used to compute HRV and PTT robustly and accurately in ambulatory settings is also described. The developed device has also been validated and compared with other commercial systems obtaining similar results. In this way, based on the quality of the obtained signals and the low variability of the computed parameters, even in ambulatory conditions, the developed device can potentially serve as a support tool for clinical decision-taking stages.


Assuntos
Epilepsia , Fotopletismografia , Eletrocardiografia/métodos , Epilepsia/diagnóstico , Frequência Cardíaca/fisiologia , Humanos , Monitorização Ambulatorial , Pacientes Ambulatoriais , Fotopletismografia/métodos , Processamento de Sinais Assistido por Computador
13.
Transplant Cell Ther ; 27(5): 424.e1-424.e9, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33965182

RESUMO

HLA-haploidentical transplantation (haplo-HCT) using post-transplantation-cyclophosphamide (PT-Cy) is a feasible procedure in children with malignancies. However, large studies on Haplo-HCT with PT-Cy for childhood acute lymphoblastic leukemia (ALL) are lacking. We analyzed haplo-HCT outcomes in 180 children with ALL. Median age was 9 years, and median follow-up was 2.7 years. Disease status was CR1 for 24%, CR2 for 45%, CR+3 for 12%, and active disease for 19%. All patients received PT-Cy day +3 and +4. Bone marrow (BM) was the stem cell source in 115 patients (64%). Cumulative incidence of 42-day engraftment was 88.9%. Cumulative incidence of day-100 acute graft-versus-host disease (GVHD) grade II-IV was 28%, and 2-year chronic GVHD was 21.9%. At 2 years, cumulative incidence of nonrelapse mortality (NRM) was 19.6%. Cumulative incidence was 41.9% for relapse and 25% for patients in CR1. Estimated 2-year leukemia free survival was 65%, 44%, and 18.8% for patients transplanted in CR1, CR2, CR3+ and 3% at 1 year for active disease. In multivariable analysis for patients in CR1 and CR2, disease status (CR2 [hazard ratio {HR} = 2.19; P = .04]), age at HCT older than 13 (HR = 2.07; P = .03) and use of peripheral blood stem cell (PBSC) (HR = 1.98; P = .04) were independent factors associated with decreased overall survival. Use of PBSC was also associated with higher NRM (HR = 3.13; P = .04). Haplo-HCT with PT-Cy is an option for children with ALL, namely those transplanted in CR1 and CR2. Age and disease status remain the most important factors for outcomes. BM cells as a graft source is associated with improved survival.


Assuntos
Leucemia-Linfoma Linfoblástico de Células Precursoras , Transplante Haploidêntico , Criança , Ciclofosfamida/uso terapêutico , Humanos , Leucemia-Linfoma Linfoblástico de Células Precursoras/terapia , Estudos Retrospectivos , Condicionamento Pré-Transplante
14.
Sensors (Basel) ; 21(7)2021 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-33810419

RESUMO

Endonasal surgery is a minimally invasive approach for the removal of pituitary tumors (sarcomas). In this type of procedure, the surgeon has to complete the surgical maneuvers for sarcoma resection with extreme precision, as there are many vital structures in this area. Therefore, the use of robots for this type of intervention could increase the success of the intervention by providing accurate movements. Research has focused on the development of teleoperated robots to handle a surgical instrument, including the use of virtual fixtures to delimit the working area. This paper aims to go a step further with a platform that includes a teleoperated robot and an autonomous robot dedicated to secondary tasks. In this way, the aim is to reduce the surgeon's workload so that he can concentrate on his main task. Thus, the article focuses on the description and implementation of a navigator that coordinates both robots via a force/position control. Finally, both the navigation and control scheme were validated by in-vitro tests.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Masculino
16.
J Med Virol ; 92(2): 260-262, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31579928

RESUMO

Serological testing for immunoglobulin M (IgM) antibodies to Hepatitis E virus (HEV) is useful for diagnosing acute hepatitis E. Our aim was to evaluate the performance of chemiluminescence immunoassay (HEV IgM; Vircell, Granada, Spain) in comparison with a manual enzyme immunoassay (Anti-HEV virus; Wantai, Beijing, China) for anti-HEV IgM detection. Seventeen HEV-RNA positive and 69 HEV-RNA negative sera were tested by both assays. Virclia sensitivity was 94.1%, whereas that of the enzyme immunosorbent assay (EIA) was 76.5%; specificity was 98.5% and 97.1% for Virclia and EIA, respectively. Differences between both assays were not statistically significant. Virclia HEV IgM showed excellent performance and can be a good alternative to conventional enzyme immunoassays for the detection of IgM against HEV.


Assuntos
Anticorpos Antivirais/sangue , Hepatite E/sangue , Hepatite E/diagnóstico , Hepatite E/imunologia , Técnicas Imunoenzimáticas/métodos , Medições Luminescentes/métodos , Vírus da Hepatite E/imunologia , Humanos , Imunoensaio/métodos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Sensibilidade e Especificidade , Soroconversão , Testes Sorológicos/métodos
17.
Am J Hematol ; 95(1): 28-37, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31625177

RESUMO

A total of 192 pediatric patients, median age 8.6 years, with high-risk hematological malignancies, underwent haploidentical stem cell transplantation (haplo-HSCT) using post-transplantation cyclophosphamide (PT-Cy), or ex vivo T cell-depleted (TCD) graft platforms, from January 1999 to December 2016 in 10 centers in Spain. Some 41 patients received an unmanipulated graft followed by PT-Cy for graft-vs-host disease (GvHD) prophylaxis. A total of 151 patients were transplanted with CD3-depleted peripheral blood stem cells (PBSCs) by either CD34+ selection, CD3+ CD19+ depletion, TCRαß+ CD19+ depletion or CD45RA+ depletion, added to CD34+ selection for GvHD prophylaxis. The PBSCs were the only source in patients following ex vivo TCD haplo-HSCT; bone marrow was the source in 9 of 41 patients following PT-CY haplo-HSCT. Engraftment was achieved in 91.3% of cases. A donor younger than 30 years, and the development of chronic GvHD were positive factors influencing survival, whereas positive minimal residual disease (MRD) before transplant and lymphoid disease were negative factors. The probability of relapse increased with lymphoid malignancies, a donor killer-cell immunoglobulin-like receptor (KIR) haplotype A and positive MRD pretransplant. No difference was found in overall survival, disease-free survival or relapse incidence between the two platforms. Relapse is still of concern in both platforms, and it should be the focus of future efforts. In conclusion, both platforms for haplo-HSCT were effective and could be utilized depending on the comfort level of the center.


Assuntos
Leucemia/terapia , Transplante Haploidêntico , Transplante de Medula Óssea/métodos , Transplante de Medula Óssea/mortalidade , Criança , Ciclofosfamida/uso terapêutico , Feminino , Sobrevivência de Enxerto , Doença Enxerto-Hospedeiro/prevenção & controle , Neoplasias Hematológicas/terapia , Transplante de Células-Tronco Hematopoéticas/métodos , Transplante de Células-Tronco Hematopoéticas/mortalidade , Humanos , Leucemia/mortalidade , Depleção Linfocítica , Masculino , Pediatria/métodos , Recidiva , Estudos Retrospectivos , Espanha , Análise de Sobrevida
18.
Sensors (Basel) ; 19(19)2019 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-31590351

RESUMO

Blood pressure wave monitoring provides interesting information about the patient's cardiovascular function. For this reason, this article proposes a non-invasive device capable of capturing the vibrations (pressure waves) produced by the carotid artery by means of a pressure sensor encapsulated in a closed dome filled with air. When the device is placed onto the outer skin of the carotid area, the vibrations of the artery will exert a deformation in the dome, which, in turn, will lead to a pressure increase in its inner air. Then, the sensor inside the dome captures this pressure increase. By combining the blood pressure wave obtained with this device together with the ECG signal, it is possible to help the screening of the cardiovascular system, obtaining parameters such as heart rate variability (HRV) and pulse transit time (PTT). The results show how the pressure wave has been successfully obtained in the carotid artery area, discerning the characteristic points of this signal. The features of this device compare well with previous works by other authors. The main advantages of the proposed device are the reduced size, the cuffless condition, and the potential to be a continuous ambulatory device. These features could be exploited in ambulatory tests.


Assuntos
Monitorização Ambulatorial da Pressão Arterial/métodos , Pressão Sanguínea/fisiologia , Monitorização Fisiológica , Análise de Onda de Pulso/métodos , Adulto , Monitorização Ambulatorial da Pressão Arterial/instrumentação , Eletrocardiografia/métodos , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Fotopletismografia/métodos , Análise de Onda de Pulso/instrumentação , Transdutores
19.
Med Biol Eng Comput ; 57(11): 2389-2405, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31473945

RESUMO

Self-management of blood glucose level is part and parcel of diabetes treatment, which involves invasive, painful, and uncomfortable methods. A proper non-invasive blood glucose monitor (NIBGM) is therefore desirable to deal better with it. Microwave resonators can potentially be used for such a purpose. Following the positive results from an in vitro previous work, a portable device based upon a microwave resonator was developed and assessed in a multicenter proof of concept. Its electrical response was analyzed when an individual's tongue was placed onto it. The study was performed with 352 individuals during their oral glucose tolerance tests, having four measurements per individual. The findings revealed that the accuracy must be improved before the diabetes community can make real use of the device. However, the relationship between the measuring parameter and the individual's blood glucose level is coherent with that from previous works, although with higher data dispersion. This is reflected in correlation coefficients between glycemia and the measuring magnitude consistently negative, although small, for the different datasets analyzed. Further research is proposed, focused on system improvements, individual calibration, and multitechnology approach. The study of the influence of other blood components different to glucose is also advised. Graphical abstract.


Assuntos
Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Adulto , Calibragem , Desenho de Equipamento , Estudos de Viabilidade , Teste de Tolerância a Glucose , Humanos , Micro-Ondas , Pessoa de Meia-Idade , Estudo de Prova de Conceito , Língua/química , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...